°ª«×¥[³t¹Ø©R¸ÕÅç¾÷(HAST)³W®æªí

MODEL

HAST-A

¤º³¡¤Ø¤o(Internal Dimension *L cm)

40*45(50L)

¥~³¡¤Ø¤o
(External Dimension W*D*H cm)

115*115*167

´`Àô¤èªk(Circulated Method)

°¨¹FÅX°ÊºÏ©Ê­·®°¾÷ºc´`Àô(·Å«×/Àã«×¤À§G§¡¤Ã¨Î)
Magnet drive circulating fan system (Temp. / Humidity superior uniformity)
ªí²{Performance

·Å«×½d³ò
(Temperature Range)

105¢J¡ã143¢J

Àã«×½d³ò
(Humidity Range)

75¢H¡ã100¢H / 105¢J¡ã143¢J

¥[¼ö®É¶¡(Heating Time)

R. t.¡ã130¢J 85%(100min)

À£¤O(Pressure)

1.2¡ã4.00kg¡]¬Û¹ïÀ£¤O§t1¤j®ðÀ£¡^

·Å«×¤À§G§¡¤Ã«×
(Temperature Uniformity)

¡Ó1.0 ¢J

Àã«×¤À§G§¡¤Ã«×
(Humidity Uniformity)

¡Ó5.0¢H

±±¨î
Control

±±¨î¾¹(Control Method)

HAST - 2005¹q¸£¤u·~±±¨î­±ªO¡A¨ã³Æ¦³8.4 "TFT±m¦âLCD (800*600)ªº±±¨î¾¹-¤¤¤å¹Ï¥ÜÅã¥Ü·Å«×/·Ã«×/·Ã²y·Å«×±±¨î¤ÎÅã¥Ü¡FÀ£¤O/DCV¹qÀ£¡G0.01 DCV
HAST 2005-PC
the BASED industry computer touches controls the type entire color 8.4 "TFT LCD(800X600)the controller-Chinese graphic display Temp /Humidity / Wet Bulb temp. control control and display ;
Pressure/DCV Voltage:0.01 DCV

¸ÑªR«×(Resolution)

·Å«×¡G0.01¢J/·Ã«×¡G0.1% À£¤O¡G0.01 kg /¹qÀ£¡G0.01 DCV
Temp. : 0.01 ¢J / Humidity : 0.1% Pressure : 0.01 kg / Voltage : 0.01 DCV

í©w«×(Stability)

·Å«×¡G¡Ó0.30¢J / ·Ã«×¡G¡Ó3%
Temperature : ¡Ó0.30¢J / Humidity :¡Ó3%

·Å«×·Pª¾¾¹(Sensor)

JPT(RTD)PT-100ohm

°O¿ý¾¹³nÅé
(
Recorder Software)

¾A¥ÎWindows°O¿ý¾¹³nÅé(°O¿ý·Å«×/·Ã«×¦±½u¸ê®Æ)
For Windows Recorder software (record temp./Humidity curve date)

ª«½èMaterial

Àã«×¼Ñ
(
Humidified Vessel)

¤£ù׿û§÷½èSUS#316 Stainless steel material

´ú¸Õ¼Ñ(Tested Vessel)

¤£ù׿û§÷½èSUS#316 Stainless steel material

¥~³¡´ú¸Õ¾¹
(Outside Tester)

¤£ù׿û§÷½èSUS#304 Stainless steel material

·Å«×¥[¼ö¾¹
(Temp. Heater)

±M·~·Å«×¥[¼ö¾¹¡A¨Ï¥ÎSUS#316¤£Äÿû§÷½è
Professional temp. heater by SUS#316 stainless steel material

Àã«×¥[¼ö¾¹
(Humidity Heater)

¨¾¤ô·Ã«×¥[¼ö¾¹¡A¨Ï¥ÎSUS#316¤£Äÿû§÷½è
Underwater humidity heater by SUS#316 stainless steel material

´`Àô¨t²ÎCirculated System

°¨¹F(Motor)

¤é¥»»s§CÂà³t¶Ç°Ê´`Àô°¨¹F
Low speed start gear-shift circulating motor made by Japan

ºÏ©Ê¶Ç¿é(Magnetic Transmission)

ºÏ©ÊµL¶b¤¤¥¡¶Ç°Ê¸Ë¸m
Magnetic un-axle center gear

­ì²z(Principle)

¥iÀ£ÁY´`Àô­·®°
Coercible circulating fan converted

­·®°(Fan)

¾T¦Xª÷­·¦V¼Ð´`Àô­·®°
Aluminum alloy vane circulating fan

¦w¥þ¨t²Î(Security System)

·Pª¾¾¹«OÅ@/²Ä¤@¶¥¬q°ª·Å«OÅ@/²Ä¤@¶¥¬q°ªÀ£«OÅ@/DCV¹qÀ£ºÊ±±/¹B§@ªùÀ£¤O­­¨î/¦Û°Ê¯}¯uªÅ/¤â°Êµ¹¤ô/¿ù»~©Î°±¾÷¦Û°Ê¬ªÀ£/±Æ¤ôÀx¦s¤ô¼Ñ/¿ù»~­ì¦]Åã¥Ü¤Î±Æ¸Ñ°Ñ¦Ò/°O¿ý¿ù»~¥\¯à±µ¦a¬ªº|/²Ä¤G¶¥¬q°ª·Å«OÅ@/²Ä¤G¶¥¬q°ªÀ£«OÅ@/²Ä¤T¶¥¬qºò«æ¬ªÀ£/·Å«×¥[¼ö¾¹¶W·Å«OÅ@/·Ã«×¥[¼ö¾¹°ª·Å«OÅ@/°¨¹F¹L¸ü«OÅ@/¿ù»~°»´ú¤Î¦w¥þ«OÅ@
Sensor protection / 1 st. stage overhead protection / 1 st. stage high-pressure protection/ DCV voltage monitor / Operating door pressure limitation / Automatic break vacuum / Manual supply water / Automatic decompression by error or stop / Drain steam stored water tank / Display error reason and reference of trouble shooting / Record error history function. Earth leakage / 2nd. stage overheat protection / 2nd. stage high-pressure protection / 3nd. stage urgent decompression protection / Temp. heater overheat protection / Humidity heater overheat protection / Motor overload protection / Error diagnose & secure protection

¼Ð·Çªþ¥ó(Standard Accessories)

¾A¥ÎWindows 98/NT/2000/XP·Å«×¤Î·Ã«×¸ê®Æ°O¿ý¾¹/¥iµ{¦¡®É§Ç´¡®yx3²Õ
For Windows 98/NT/2000/XP temp. & humidity data recorder / programmable time signal socketsx 3 sets

¿ï¾Üªþ¥ó(Optional Accessories)

·Å«×/·Ã«×/À£¤OD/A (12bit)°O¿ý¾¹¤¶­±/YEW°O¿ý¾¹/BIAS´ú¸Õ¾÷¨î/¹q·½¨ÑÀ³/e¤ÆºÞ²z¨t²Î/ BIAS¹qÀ£ºÝ¤l*20²Õ
Temp. / humidity / pressure D/A (12bit) recorder interface / YEW recorder / BIAS test mechanism /Power supply / e manage system / BIAS voltage terminal * 20 sets.

¹q·½(Power Source)

AC 220V

¦w°ö(Ampere)

18A

²b­«(Net Weight)

550kg 

 ¡°¥H¤W³W®æ¶È¨Ñ°Ñ¦Ò¡A¦p¦³Åܧ󤣥t¦æ³qª¾¡C